Fire Alarm Systems

Leading Manufacturer of water flow detectors system sensor, water flow detector switch, standalone type battery operated smoke detector and standalone type smoke detector from New Delhi.

Water Flow Detectors System Sensor

₹ 4550/Piece Get Latest Price

Product Brochure
Usage/ApplicationFire Fighting Installation
Model Name/NumberWFD 25 / WFD 30 / WFD 40 / WFD 60 / WFD 80
Sensor TypeVane Type
Flow Rate4-10 GPM
Operating Pressure250 PSi (Max)
BrandSystem Sensor
Flow MediaWater

Minimum order quantity: 1 Piece

WFDN Series Waterflow Detectors
The WFDN Series detectors provide an easy to see, feel, and set time delay mechanism. The timer dial is large and easy to turn, with high contrast pad-printed markings. Set by feel in dimly lit locations with tactile features for approximate setting at 30 and 60 seconds. The delay/switch assembly is fi eld replaceable for ease of maintenance.
WFDN Series Waterfl ow Detectors Model Pipe Size Hole Size Pressure Rating Contact Ratings Triggering Threshold WFD20N 2 in. 1¼ in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4–10 GPM WFD25N 2½ in. 1¼ in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4–10 GPM WFD30N 3 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4–10 GPM WFD40N 4 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4–10 GPM WFD50N 5 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4–10 GPM WFD60N 6 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4–10 GPM WFD80N 8 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4–10 GPM
Specifications

  • Compatible Pipe Schedules:Steel water pipe, schedule 10 through 40
  • Conduit Entrances:Two openings for ½ in. conduit.
  • Contact Ratings:Two sets of SPDT (Form C) 10.0 A, ½ HP @ 125/250 VAC 2.5 A @ 6/12/24 VDC
  • Cover Tamper Switch:Optional for UL and ULC models, part no. CTS
  • Enclosure Rating:NEMA 4 – suitable for indoor/outdoor use
  • Maximum Surge:18 Feet Per Second (FPS
  • Operating Temperature Range:32°F to 150°F (0°C to 66°C
  • Pipe Size:6 inches
  • Shipping Weight:5.6 lbs
  • Static Pressure Rating:450 PSI
  • Triggering Threshold Bandwidtch (Flow Rate):4-10 GPM
  • Warranty:3 years
Agency Links
  •  
  •  

Water Flow Detector Switch

₹ 4250/Piece Get Latest Price

Product Brochure
FinishingAs per standards
Model Name/NumberAs per standards
Measurement RangeAs per standards
BrandSystem Sensor
Temperature RangeAs per standards
WeightAs per standards
Flow Media TypeLiquid

Minimum order quantity: 1 Piece

Make : System Sensor / Honeywell

WFDN Series Waterflow Detectors

The WFDN Series detectors provide an easy to see, feel, and set time delay mechanism. The timer dial is large and easy to turn, with high contrast pad-printed markings. Set by feel in dimly lit locations with tactile features for approximate setting at 30 and 60 seconds. The delay/switch assembly is field replaceable for ease of maintenance.
WFDN Series Waterfl ow Detectors Model Pipe Size Hole Size Pressure Rating Contact Ratings Triggering Threshold WFD20N 2 in. 1¼ in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4–10 GPM WFD25N 2½ in. 1¼ in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4–10 GPM WFD30N 3 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4–10 GPM WFD40N 4 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4–10 GPM WFD50N 5 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4–10 GPM WFD60N 6 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4–10 GPM WFD80N 8 in. 2 in. 450 PSI 2 Form C: 10 A, 1/2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4–10 GPM
Specifications

  • Compatible Pipe Schedules:Steel water pipe, schedule 10 through 40
  • Conduit Entrances:Two openings for ½ in. conduit.
  • Contact Ratings:Two sets of SPDT (Form C) 10.0 A, ½ HP @ 125/250 VAC 2.5 A @ 6/12/24 VDC
  • Cover Tamper Switch:Optional for UL and ULC models, part no. CTS
  • Enclosure Rating:NEMA 4 – suitable for indoor/outdoor use
  • Maximum Surge:18 Feet Per Second (FPS)
  • Operating Temperature Range:32°F to 150°F (0°C to 66°C)
  • Pipe Size:6 inches
  • Shipping Weight:5.6 lbs.
  • Static Pressure Rating:450 PSI
  • Triggering Threshold Bandwidtch (Flow Rate):4-10 GPM
  • Warranty:3 years
Agency Links

Standalone Type Battery Operated Smoke Detector

₹ 400/1 pices Get Latest Price

Product Brochure
Product TypeSmoke Detector
BrandFORCE
Usage/ApplicationOffice Buildings
Alarm Sensor TypePhotoelectric
Power Source9V DC
ColorWhite
MaterialABS
Alarm CurrentAs per Standards
Alarm IndicationAs per Standards
Alarm ResponseAs per Standards
Design TypeAs per Standards
Operating Temp.As per Standards
ShapeRound
Alarm NoiseAs per Standards
UsageResidential Buildings, Office Buildings, Industrial Premises
Model/TypeStand Alone Type
I Deal InNew Only
WirelessYes

Minimum order quantity: 1 1 pices

Make: FORCE

Battery Operated
Standalone Type

Main feature :-


  • Manual test , Auto-reset
  • Photoelectric sensor
  • Sound & flash alarm
  • Single sided fiberglass PCB
  • High stability to the environment
  • High density SMT design,high stability
  • Dust-proof, moth-proof and anti-white light

 

Technical parameter :-
  • Rated voltage: 9VDC
  • Alarm decibel: 85dB for 10feet
  • Static current: 10uA
  • Alarm current: 15mA
  • Working temperature: -10°C~+50°C
  • Humidity: 95%RH
  • Alarm mode: sound & flash
  • Monitoring area: 20 square meter
  • Size: 107*35mm
  • Execute criterion:GB4715-1993

VAT Extra.

Standalone Type Smoke Detector

₹ 350/Piece Get Latest Price

Product Brochure
Product TypeSmoke Detector
BrandAQUA
Usage/ApplicationOffice Buildings
TypeWireless
Power Source9V Battery
CertificationCE
UsageIndustrial Premises, Office Buildings, Residential Buildings
Model/TypeBattery-Operated
Country of OriginChina

Minimum order quantity: 100 Piece

AQUA make.
Standalone type. 

We offer Smoke Detectors as one of our products. These smoke detectors are installed in buildings according to the nature of fire risk.

These are offered with the following features:

  • Low current draw
  • Stable performance in high air velocities
  • Built in tamper resistant base design etc.